Detailed · Deep study
1Half-life
The time taken for half the nuclei of that isotope in any sample to decay.
Each isotope has its own half-life, from fractions of a second to billions of years. Because the activity (count rate) is proportional to the number of undecayed nuclei, the count rate also halves every half-life.
Worked example
Half-life calculation
A sample contains 6400 undecayed nuclei of an isotope with a half-life of 8 days. How many are left after 24 days?
- 1
Number of half-lives.
- 2
Halve three times.
Answer800 nuclei
Worked example
Finding half-life from a table
The count rate of a source falls from 480 counts/minute to 60 counts/minute in 45 minutes. Find the half-life.
- 1
480 → 240 → 120 → 60 is 3 halvings.
3 half-lives = 45 minutes
- 2
Divide.
minutes
Answer15 minutes
2Half-life with background radiation (Supplement)
If the data still include background radiation, the count rate does not fall to zero but levels off at the background rate. Subtract the background count rate from every reading first, then find the time for the corrected count rate to halve.
Worked example
Correcting first
(Supplement) Background = 20 counts/minute. Readings: 0 min, 420; 10 min, 220; 20 min, 120 counts/minute. Find the half-life.
- 1
Corrected rates.
400, 200, 100 counts/minute
- 2
Halves every 10 minutes.
half-life = 10 minutes
Answer10 minutes
3Choosing an isotope for a job (Supplement)
| Application | Radiation | Half-life | Reason |
|---|---|---|---|
| smoke alarm (americium-241) | α | long (hundreds of years) | α ionises air between plates; smoke absorbs α, so the current drops and the alarm sounds; α is stopped by the case; long half-life – no replacement needed |
| irradiating food to kill bacteria | γ | long | γ penetrates packaging and food; food does not become radioactive |
| sterilising medical equipment | γ | long | γ penetrates the sealed packaging and kills microorganisms |
| measuring / controlling thickness of paper or foil | β | long | β is partly absorbed – the amount depends on thickness (α would all be stopped, γ would all pass) |
| diagnosis (tracers) and treatment of cancer | γ | short for tracers (hours); long for external treatment sources | γ passes out of the body to a detector, or targets a tumour from several directions; short half-life gives a small dose |
Thickness control: if the sheet gets thicker, fewer β-particles reach the detector; the falling count rate makes the rollers press harder. A long half-life means the count rate does not fall noticeably over time, so changes are due only to thickness.
4Exam focus
Key words: half-life; half the nuclei decay; count rate halves; decay curve; subtract background; α smoke alarm; γ sterilising and cancer; β thickness; long or short half-life.
Quick self-check
Answer in your head first, then reveal.
The time taken for half the nuclei of that isotope in a sample to decay (1).
1/8 (1).
100 counts per minute (1).
Beta is partly absorbed by paper (1); amount absorbed changes with thickness (1); alpha would be fully absorbed / gamma would pass through unchanged (1).
Activity falls quickly / small dose to the patient (1); but long enough to complete the scan (1).