4.4

Topic 16

Electrical safety

  • IGCSE Physics 0625
  • 3 min read
  • Syllabus 2026, 2027 and 2028

Core

  1. 1

    State the hazards of:

    • adamaged insulation
    • boverheating cables
    • cdamp conditions
    • dexcess current from overloading of plugs, extension leads, single and multiple sockets when using a mains supply
  2. 2

    Know that a mains circuit consists of a live wire (line wire), a neutral wire and an earth wire and explain why a switch must be connected to the live wire for the circuit to be switched off safely

  3. 3

    Explain the use and operation of trip switches and fuses and choose appropriate fuse ratings and trip switch settings

  4. 4

    Explain why the outer casing of an electrical appliance must be either non-conducting (double-insulated) or earthed

  5. 5

    State that a fuse without an earth wire protects the circuit and the cabling for a double-insulated appliance

Cambridge IGCSE Physics 0625 syllabus 2026-2028, 4.4 Electrical safety (copied for internal use as permitted by Cambridge)

Detailed · Deep study

1Hazards

HazardDanger
damaged insulationbare live wire can be touched → electric shock; can cause a short circuit and fire
overheating cablestoo much current heats cables → insulation melts → fire
damp conditionswater conducts → electric shock
overloading plugs, extension leads and socketstoo many appliances draw excess current → cables overheat → fire

2Mains wiring

Fig. 1Live, neutral and earth.
  • Live wire (line): carries the alternating high p.d. from the supply.
  • Neutral wire: completes the circuit; it is at (nearly) zero p.d.
  • Earth wire: a safety wire connected to the metal case of an appliance; normally no current flows in it.

The switch must be in the live wire: then when the switch is off, the appliance is disconnected from the high voltage. If the switch were in the neutral wire, the appliance would still be connected to the live wire when "off", and touching a faulty part could still give a shock.

3Fuses and trip switches

  • A fuse is a thin wire that melts when the current exceeds its rating, breaking the circuit. It is placed in the live wire.
  • A trip switch (circuit breaker) switches off automatically when the current is too large. It can be reset, and it acts faster than a fuse.

Worked example

Choosing a fuse

A 2.3 kW kettle runs on 230 V mains. Fuses of 3 A, 5 A and 13 A are available. Which should be used?

  1. 1

    Normal current.

  2. 2

    Choose the next rating above.

    13 A

Answer13 A

4Earthing and double insulation

If a live wire touches a metal case, the case becomes live and anyone touching it could get a shock. With an earth wire connected to the case, a large current flows from live to earth, which blows the fuse (or trips the circuit breaker) and disconnects the supply. So the outer casing must be either earthed or non-conducting.

Double-insulated appliances have a plastic case (and extra insulation inside), so the case cannot become live. They need no earth wire; the fuse still protects the circuit and cabling from excess current.

5Exam focus

Key words: damaged insulation; overheating; damp; overloading; live, neutral, earth; switch in the live wire; fuse melts; trip switch; rating just above normal current; earthed metal case; double-insulated.

Quick self-check

Answer in your head first, then reveal.

  1. So that when off, the appliance is not connected to the high voltage / live (1); prevents shock when touching it (1).

  2. Large current flows to earth (1); fuse melts / breaks the circuit (1); case is no longer live (1).

  3. 5 A (1).

  4. Water conducts so risk of electric shock (1).

Finished this subtopic? Track it on your subject page.