Detailed · Deep study
1Hazards
| Hazard | Danger |
|---|---|
| damaged insulation | bare live wire can be touched → electric shock; can cause a short circuit and fire |
| overheating cables | too much current heats cables → insulation melts → fire |
| damp conditions | water conducts → electric shock |
| overloading plugs, extension leads and sockets | too many appliances draw excess current → cables overheat → fire |
2Mains wiring
- Live wire (line): carries the alternating high p.d. from the supply.
- Neutral wire: completes the circuit; it is at (nearly) zero p.d.
- Earth wire: a safety wire connected to the metal case of an appliance; normally no current flows in it.
The switch must be in the live wire: then when the switch is off, the appliance is disconnected from the high voltage. If the switch were in the neutral wire, the appliance would still be connected to the live wire when "off", and touching a faulty part could still give a shock.
3Fuses and trip switches
- A fuse is a thin wire that melts when the current exceeds its rating, breaking the circuit. It is placed in the live wire.
- A trip switch (circuit breaker) switches off automatically when the current is too large. It can be reset, and it acts faster than a fuse.
Worked example
Choosing a fuse
A 2.3 kW kettle runs on 230 V mains. Fuses of 3 A, 5 A and 13 A are available. Which should be used?
- 1
Normal current.
- 2
Choose the next rating above.
13 A
Answer13 A
4Earthing and double insulation
If a live wire touches a metal case, the case becomes live and anyone touching it could get a shock. With an earth wire connected to the case, a large current flows from live to earth, which blows the fuse (or trips the circuit breaker) and disconnects the supply. So the outer casing must be either earthed or non-conducting.
Double-insulated appliances have a plastic case (and extra insulation inside), so the case cannot become live. They need no earth wire; the fuse still protects the circuit and cabling from excess current.
5Exam focus
Key words: damaged insulation; overheating; damp; overloading; live, neutral, earth; switch in the live wire; fuse melts; trip switch; rating just above normal current; earthed metal case; double-insulated.
Quick self-check
Answer in your head first, then reveal.
So that when off, the appliance is not connected to the high voltage / live (1); prevents shock when touching it (1).
Large current flows to earth (1); fuse melts / breaks the circuit (1); case is no longer live (1).
5 A (1).
Water conducts so risk of electric shock (1).